Classic AutoAir Perfect Fit-Elite Series Instrucciones de operaciones Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
12
Locate the Defrost / Heat Duct Assembly.
Attach to evaporator using (2) #10 x 5/8 pan
head Philips screws. Be sure that the S-clips
are pressed over the rear flange. This helps
secure the duct assembly.
Locate 2” dia flex hose (1) piece 2’ long and
attach it to right outlet as shown.
Find (1) piece of 2” dia. flex hose 3’ long and
attach it to left outlet. Route hose down and
behind the micro switch assembly.
Locate wire harness from the evaporator electric actuator and attach to the (2) micro switches.
Refer to the wiring diagram on next page.
Attach Wire Harness supplied in unit to the blower switch. Route harness through the control
opening. Attach wire harness to left micro-switch on Defrost Duct assembly. Route harness
across top of the unit and hookup the resistor, and blower motor. Route the blue clutch wire over
evaporator and out through hole in the firewall block off plate.
BLUE WIRE FROM BLOWER
SWITCH
BLUE WIRE TO THE
THERMOSTAT
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 26 27

Comentarios a estos manuales

Sin comentarios